| Mfr Part # | Qty | Price | Product Status | Type | Function | Actuator Type | Operating Pressure | Orifice Diameter | Fluid Type | Connection Method | For Use With/Related Products | Mounting Type | Features | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
VBF3JU1SRB/M
3-WAY ACTUATED CONTROL BALL VALV
Honeywell
|
23 | 1900.79000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
VBF2L11SRC/M
2-WAY ACTUATED CONTROL BALL VALV
Honeywell
|
23 | 3459.20000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
APQ-20-16-P1-L
GEAR PUMP, SAE A 2 BOLT, 16 CC
Anfield Industries
|
3,065 | 115.00000 | Active | Gear Pump | Pressure Operated | - | 2900 PSI (200 bar) | - | - | Threaded | - | Sub-Base Mount | - | Details |
|
VBF3J11S0B/M
3-WAY ACTUATED CONTROL BALL VALV
Honeywell
|
23 | 1343.70000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
HE-N1-LO
SHUT-OFF VALVE
Festo Corporation
|
2 | 362.31000 | Active | Control Valve, Maintained | - | - | 15 ~ 145 PSI (1 ~ 10 bar) | - | Air, Inert Gas | Threaded 1" NPT | - | Sub-Base Mount | - | Details |
|
81529003
FLOW RESTRICT ONE-WAY FREE HANG
Crouzet
|
2,403 | 31.98000 | Active | Flow Restrictor, Fixed | One-Way | - | 15 ~ 116 PSI (1 ~ 8 bar) | 0.012" (0.30mm) | Air, Inert Gas | Push-In Connection for Tubing 5/32" (4.00mm) Dia | - | Free Hanging (In-Line) | - | Details |
|
SOL1A1
VALVE SOLENOID 3/8" BSP NO 24VDC
Sensata-Cynergy3
|
1 | 339.34000 | Active | Solenoid Valve | 2/2 Normally Open, One-Way | - | 1 ~ 218 PSI (0.1 ~ 15 bar) | - | Inert Gas, Liquid | Threaded 3/8" BSP | - | Free Hanging (In-Line) | Supply Voltage 24VDC | Details |
|
BM-92-312/2-HNR-156
2 X 3/2-WAY NO, ELECTRICALLY OPE
AIRTEC Pneumatics
|
5 | 139.73000 | Active | Solenoid Valve | 2 x 3/2 Normally Open | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount | Supply Voltage 115VAC | Details |
|
VUVS-L30-M32C-MD-N38-F8
SOLENOID VALVE
Festo Corporation
|
3 | 78.66000 | Active | Solenoid Valve | 3/2 Normally Closed | - | 36 ~ 145 PSI (2.5 ~ 10 bar) | - | Air, Inert Gas, Liquid | Threaded | - | Sub-Base Mount | - | Details |
|
B6250S-070-250+ARX24-MFT
CCV,2.5",2 WAY,70 CV,W/NON-SPRIN
Belimo
|
58 | 1415.70000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
VBF2K21S0X/M
2-WAY ACTUATED CONTROL BALL VALV
Honeywell
|
23 | 1967.01000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
VZBE-11/2-T-63-T-2-F0507-V15V15
BALL VALVE
Festo Corporation
|
2 | 329.82000 | Active | Control Valve, Maintained | 2/2 | - | - | - | Air, Inert Gas, Liquid | Threaded | - | Free Hanging (In-Line) | - | Details |
|
81540005
LOGIC OR ELEMENT SUB-BASE MOUNT
Crouzet
|
7,888 | 34.00000 | Active | Logic Element | LOGIC OR | - | 30 ~ 116 PSI (2 ~ 8 bar) | 0.106" (2.70mm) | Air, Inert Gas | - | - | Sub-Base Mount | Pressure Indicator | Details |
|
MS6-EE-1/2-10V24-S
ON-OFF VALVE
Festo Corporation
|
8 | 249.36000 | Active | Control Valve, Maintained | 3/2 Normally Closed | - | 58 ~ 145 PSI (4 ~ 10 bar) | - | Air, Inert Gas, Liquid | Threaded | - | Sub-Base Mount | - | Details |
|
VBF3L51S0A/M
3-WAY ACTUATED CONTROL BALL VALV
Honeywell
|
23 | 2795.66000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
BM-92-534-HNR-131
5/3-WAY, ELECTRICALLY OPERATED P
AIRTEC Pneumatics
|
10 | 143.10000 | Active | Solenoid Valve | 5/3 | - | 44 ~ 116 PSI (3 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount | Supply Voltage 12VDC | Details |
|
MS4N-EM1-1/4
ON-OFF VALVE
Festo Corporation
|
3 | 77.86000 | Active | Control Valve, Maintained | 3/2 Normally Closed | - | 0 ~ 203 PSI (0 ~ 14 bar) | - | Air, Inert Gas, Liquid | Threaded | - | Sub-Base Mount | - | Details |
|
81513533
SWITCH PRESSURE OPERATED CHAS MT
Crouzet
|
1 | 100.06000 | Active | Pressure Switch | Pressure Operated | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas, Liquid | Threaded 1/8" BSP | - | Chassis Mount | - | Details |
|
BM-92-534-HNR-152
5/3-WAY, ELECTRICALLY OPERATED P
AIRTEC Pneumatics
|
10 | 147.90000 | Active | Solenoid Valve | 5/3 | - | 44 ~ 116 PSI (3 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount | Supply Voltage 24VAC | Details |
|
VBF2KU1SRD/M
2-WAY ACTUATED CONTROL BALL VALV
Honeywell
|
23 | 2746.16000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
B6400S-186-250+GRX24-3-T N4
CCV,4",2 WAY,186 CV,W/NON-SPRING
Belimo
|
58 | 2150.55000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
81506720
TIMER OFF-DELAY SUB-BASE MOUNT
Crouzet
|
7,540 | 274.43000 | Active | Timer, Adjustable | Off-Delay | - | 30 ~ 116 PSI (2 ~ 8 bar) | 0.106" (2.70mm) | Air, Inert Gas | - | - | Sub-Base Mount | Delay Time 0.1 ~ 30sec | Details |
|
81519335
SOLENOID VALVE 3/2 NC SUBBASE MT
Crouzet
|
13 | 78.73000 | Active | Solenoid Valve | 3/2 Normally Closed | - | 15 ~ 116 PSI (1 ~ 8 bar) | 0.020" (0.50mm) | Air, Inert Gas | - | - | Sub-Base Mount | Manual Override, Supply Voltage 24VDC | Details |
|
BM-91-312/2-HNR-126
2 X 3/2-WAY NO, ELECTRICALLY OPE
AIRTEC Pneumatics
|
5 | 127.35000 | Active | Solenoid Valve | 2 x 3/2 Normally Open | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount | Supply Voltage 115VAC | Details |
Submit your RFQ and our team will source it for you.