| Mfr Part # | Qty | Price | Product Status | Type | Function | Actuator Type | Operating Pressure | Orifice Diameter | Fluid Type | Connection Method | For Use With/Related Products | Mounting Type | Features | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
81540004
LOGIC OR ELEMENT FREE HANGING
Crouzet
|
12 | 73.19000 | Active | Logic Element | LOGIC OR | - | 30 ~ 116 PSI (2 ~ 8 bar) | 0.106" (2.70mm) | Air, Inert Gas | Push-In Connection for Tubing 5/32" (4.00mm) Dia | - | Free Hanging (In-Line) | - | Details |
|
GRLA-1/2-QS-12-RS-D
ONE-WAY FLOW CONTROL VALVE
Festo Corporation
|
2 | 91.34000 | Active | Flow Restrictor, Adjustable | One-Way | - | 3 ~ 145 PSI (0.2 ~ 10 bar) | - | Air, Inert Gas, Liquid | Threaded | - | Sub-Base Mount | - | Details |
|
BM-91-312-HNR-127
3/2-WAY NO, ELECTRICALLY OPERATE
AIRTEC Pneumatics
|
10 | 127.35000 | Active | Solenoid Valve | 3/2 Normally Open | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount | Supply Voltage 230VAC | Details |
|
BM-91-520-HNR-127
5/2-WAY, ELECTRICALLY OPERATED P
AIRTEC Pneumatics
|
10 | 103.65000 | Active | Solenoid Valve | 5/2 | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount | Supply Voltage 230VAC | Details |
|
GRLA-3/8-QB-1/2-U
ONE-WAY FLOW CONTROL VALVE
Festo Corporation
|
20 | 41.76000 | Active | Flow Restrictor, Adjustable | One-Way | - | -14 ~ 116 PSI (-1 ~ 8 bar) | - | Air, Inert Gas, Liquid | Threaded 2-3/8" NPT | - | Sub-Base Mount | - | Details |
|
81290501
POSITION DETECT 3/2 NO CHAS MNT
Crouzet
|
57 | 58.07000 | Active | Position Detector | 3/2 Normally Open | Round (Pin Plunger) | 44 ~ 116 PSI (3 ~ 8 bar) | 0.079" (2.00mm) | Air, Inert Gas | Barbed Connection for Tubing 5/32" (4.00mm) Dia | - | Chassis Mount | Operating Force 0.5N | Details |
|
BM-92-511-HNR-162
5/2 WAY, ELECTRICALLY OPERATED P
AIRTEC Pneumatics
|
25 | 82.38000 | Active | Solenoid Valve | 5/2 | - | 44 ~ 116 PSI (3 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount | Supply Voltage 24VDC | Details |
|
BM-91-511-HNR-126
5/2-WAY, ELECTRICALLY OPERATED P
AIRTEC Pneumatics
|
20 | 78.60000 | Active | Solenoid Valve | 5/2 | - | 44 ~ 116 PSI (3 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount | Supply Voltage 115VAC | Details |
|
MS6-SV-1/2-D-10V24P-2M12-SO-AG
SOFT-START/QUICK EXHAUST VALVE
Festo Corporation
|
6,443 | 1269.98000 | Active | Control Valve, Maintained | 3/2 Normally Closed | - | 51 ~ 145 PSI (3.5 ~ 10 bar) | - | Air, Inert Gas, Liquid | Threaded | - | Sub-Base Mount | - | Details |
|
81921902
POSITION DETECT 3/2 NO CHAS MNT
Crouzet
|
5,725 | 119.91000 | Active | Position Detector | 3/2 Normally Open | Lever, Roller | 1 ~ 116PSI (0.1 ~ 8 bar) | 0.106" (2.70mm) | Air, Inert Gas | Push-In Connection for Tubing 6.00mm Dia | - | Chassis Mount | Operating Force 18N | Details |
|
GMCU 04-04
FLOW CONTROL VALVE - ONE WAY
Camozzi Automation
|
50 | 22.54000 | Active | Flow Control, Adjustable | Meter Out | Manual Knob | 14.5 ~ 145 PSI (1 ~ 10 bar) | - | Filtered Air | Threaded 1/4" NPT | 1/4" OD Tube | - | - | Details |
|
BM-91-312-HNR-157
3/2-WAY NO, ELECTRICALLY OPERATE
AIRTEC Pneumatics
|
10 | 127.35000 | Active | Solenoid Valve | 3/2 Normally Open | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount | Supply Voltage 230VAC | Details |
|
APQ-20-25-P-L
GEAR PUMP, SAE A 2 BOLT, 25 CC
Anfield Industries
|
8,522 | 115.00000 | Active | Gear Pump | Pressure Operated | - | 2900 PSI (200 bar) | - | - | Threaded | - | Sub-Base Mount | - | Details |
|
GRLA-3/8-QS-6-D
ONE-WAY FLOW CONTROL VALVE
Festo Corporation
|
5 | 36.18000 | Active | Flow Restrictor, Adjustable | One-Way | - | 3 ~ 145 PSI (0.2 ~ 10 bar) | - | Air, Inert Gas, Liquid | Threaded | - | Sub-Base Mount | - | Details |
|
B352
CCV, 3-WAY, SS TRIM, 2", CV 83
Belimo
|
58 | 481.50000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
GRLA-1/8-QB-5/32-U
ONE-WAY FLOW CONTROL VALVE
Festo Corporation
|
20 | 28.94000 | Active | Flow Restrictor, Adjustable | One-Way | - | -14 ~ 116 PSI (-1 ~ 8 bar) | - | Air, Inert Gas, Liquid | Threaded 2-1/8" NPT | - | Sub-Base Mount | - | Details |
|
BM-91-520-HNR-156
5/2-WAY, ELECTRICALLY OPERATED P
AIRTEC Pneumatics
|
10 | 103.65000 | Active | Solenoid Valve | 5/2 | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount | Supply Voltage 115VAC | Details |
|
81522501
LOGIC AND ELEMENT SUB-BASE MOUNT
Crouzet
|
52 | 20.64000 | Active | Logic Element | LOGIC AND | - | 30 ~ 116 PSI (2 ~ 8 bar) | 0.106" (2.70mm) | Air, Inert Gas | - | - | Sub-Base Mount | Pressure Indicator | Details |
|
VBF3L21SRB/M
3-WAY ACTUATED CONTROL BALL VALV
Honeywell
|
23 | 3777.60000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
BM-92-314/2-HNR-126
2 X 3/2-WAY NO/NC, ELECTRICALLY
AIRTEC Pneumatics
|
5 | 139.73000 | Active | Solenoid Valve | 2 x 3/2 Normally Closed/Normally Open | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount | Supply Voltage 115VAC | Details |
|
81506710
TIMER OFF-DELAY SUB-BASE MOUNT
Crouzet
|
5,615 | 177.82200 | Active | Timer, Adjustable | Off-Delay | - | 30 ~ 116 PSI (2 ~ 8 bar) | 0.106" (2.70mm) | Air, Inert Gas | - | - | Sub-Base Mount | Delay Time 0.1 ~ 15sec | Details |
|
MPV-3B-NV
3/16" X 3/16" BARBED NYLON DIAPH
Pneuline Supply
|
100 | 2.52500 | Active | Non-Return Valve (Check Valve) | - | - | 50 PSI (3.4 bar) | - | - | - | - | - | - | Details |
|
VBF3KU1SRA/M
3-WAY ACTUATED CONTROL BALL VALV
Honeywell
|
23 | 2438.31000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
BM-91-533-HNR-132
5/3-WAY, ELECTRICALLY OPERATED P
AIRTEC Pneumatics
|
10 | 121.73000 | Active | Solenoid Valve | 5/3 | - | 44 ~ 116 PSI (3 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount | Supply Voltage 24VDC | Details |
Submit your RFQ and our team will source it for you.