| Mfr Part # | Qty | Price | Product Status | Type | Function | Actuator Type | Operating Pressure | Orifice Diameter | Fluid Type | Connection Method | For Use With/Related Products | Mounting Type | Features | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
81506920
FREQ GENERATOR SUB-BASE MOUNT
Crouzet
|
6 | 190.31000 | Active | Frequency Generator | - | - | 30 ~ 116 PSI (2 ~ 8 bar) | 0.106" (2.70mm) | Air, Inert Gas | - | - | Sub-Base Mount | - | Details |
|
GRLA-3/8-QS-6-RS-D
ONE-WAY FLOW CONTROL VALVE
Festo Corporation
|
5 | 41.49000 | Active | Flow Restrictor, Adjustable | One-Way | - | 3 ~ 145 PSI (0.2 ~ 10 bar) | - | Air, Inert Gas, Liquid | Threaded | - | Sub-Base Mount | - | Details |
|
BM-91-312/2-HNR-156
2 X 3/2-WAY NO, ELECTRICALLY OPE
AIRTEC Pneumatics
|
5 | 127.35000 | Active | Solenoid Valve | 2 x 3/2 Normally Open | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount | Supply Voltage 115VAC | Details |
|
GRLA-1/8-QS-8-MF-D
ONE-WAY FLOW CONTROL VALVE
Festo Corporation
|
2 | 26.92000 | Active | Flow Restrictor, Adjustable | One-Way | - | 3 ~ 145 PSI (0.2 ~ 10 bar) | - | Air, Inert Gas, Liquid | Threaded | - | Sub-Base Mount | - | Details |
|
BM-92-314/2-HNR-122
2 X 3/2-WAY NO/NC, ELECTRICALLY
AIRTEC Pneumatics
|
5 | 139.73000 | Active | Solenoid Valve | 2 x 3/2 Normally Closed/Normally Open | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount | Supply Voltage 24VDC | Details |
|
VBF3L11S0C/M
3-WAY ACTUATED CONTROL BALL VALV
Honeywell
|
23 | 2361.49000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
BM-92-312-HNR-126
3/2-WAY NO, ELECTRICALLY OPERATE
AIRTEC Pneumatics
|
5 | 75.68000 | Active | Solenoid Valve | 3/2 Normally Open | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount | Supply Voltage 115VAC | Details |
|
VBF3J21S0B/M
3-WAY ACTUATED CONTROL BALL VALV
Honeywell
|
23 | 1343.70000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
81280002
NO 80 VERS MICROVLV W/M LVR
Crouzet
|
7,449 | 58.42000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
VBF3L11S0B/M
3-WAY ACTUATED CONTROL BALL VALV
Honeywell
|
23 | 2859.98000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
SOL2A4
VALVE SOLENOID 1/2" BSP NO 220VA
Sensata-Cynergy3
|
8,164 | 196.11000 | Active | Solenoid Valve | 2/2 Normally Open, One-Way | - | 1 ~ 218 PSI (0.1 ~ 15 bar) | - | Inert Gas, Liquid | Threaded 1/2" BSP | - | Free Hanging (In-Line) | Supply Voltage 230VAC | Details |
|
VZBE-2-T-63-T-2-F0507-V15V15
BALL VALVE
Festo Corporation
|
2 | 448.81000 | Active | Control Valve, Maintained | 2/2 | - | - | - | Air, Inert Gas, Liquid | Threaded | - | Free Hanging (In-Line) | - | Details |
|
VUVS-LK20-M32C-AD-G18-1C1-S
SOLENOID VALVE
Festo Corporation
|
10 | 55.23000 | Active | Solenoid Valve | 3/2 Normally Closed | - | 22 ~ 116 PSI (1.5 ~ 8 bar) | - | Air, Inert Gas, Liquid | Threaded | - | Sub-Base Mount | Supply Voltage 24VDC | Details |
|
81513200
CONTROL VALVE 4/2 SUBBASE MNT
Crouzet
|
173 | 43.88000 | Active | Control Valve, Momentary | 4/2 | - | 44 ~ 116 PSI (3 ~ 8 bar) | 0.118" (3.00mm) | Air, Inert Gas | - | - | Sub-Base Mount | - | Details |
|
B325
CCV, 3-WAY, SS TRIM, 1", CV 30
Belimo
|
58 | 131.85000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
B308B
CCV, 3-WAY, BRASS TRIM, 1/2'', C
Belimo
|
58 | 55.35000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
SOL5A3
VALVE SOLENOID 1-1/4" BSP NO 110
Sensata-Cynergy3
|
2 | 529.91000 | Active | Solenoid Valve | 2/2 Normally Open, One-Way | - | 6 ~ 174 PSI (0.4 ~ 12 bar) | - | Inert Gas, Liquid | Threaded 1-1/4" BSP | - | Free Hanging (In-Line) | Supply Voltage 110VAC | Details |
|
B218
CCV, 2-WAY, SS TRIM, 3/4", CV 7.
Belimo
|
58 | 91.35000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
81921702
POSITION DETECT 3/2 NC CHAS MNT
Crouzet
|
148 | 74.39000 | Active | Position Detector | 3/2 Normally Closed | Lever, Roller | 1 ~ 116PSI (0.1 ~ 8 bar) | 0.106" (2.70mm) | Air, Inert Gas | Push-In Connection for Tubing 5/32" (4.00mm) Dia | - | Chassis Mount | Operating Force 18N | Details |
|
VBF3JT1S0X/M
3-WAY ACTUATED CONTROL BALL VALV
Honeywell
|
23 | 1356.67000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
SOL3A4
VALVE SOLENOID 3/4" BSP NO 220/2
Sensata-Cynergy3
|
6,269 | 265.50000 | Active | Solenoid Valve | 2/2 Normally Open, One-Way | - | 3 ~ 218 PSI (0.2 ~ 15 bar) | - | Inert Gas, Liquid | Threaded 3/4" BSP | - | Free Hanging (In-Line) | Supply Voltage 230VAC | Details |
|
VBF2L71S0A/M
2-WAY ACTUATED CONTROL BALL VALV
Honeywell
|
23 | 2588.58000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
AP-10-6.1-P2-R
GEAR PUMP, SAE AA 2 BOLT, 6.1 CC
Anfield Industries
|
3,273 | 100.00000 | Active | Gear Pump | Pressure Operated | - | 3625 PSI (250 bar) | - | - | Threaded | - | Sub-Base Mount | - | Details |
|
BM-91-312-HNR-122
3/2-WAY NO, ELECTRICALLY OPERATE
AIRTEC Pneumatics
|
10 | 127.35000 | Active | Solenoid Valve | 3/2 Normally Open | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount | Supply Voltage 24VDC | Details |
Submit your RFQ and our team will source it for you.