| Mfr Part # | Qty | Price | Product Status | Type | Function | Actuator Type | Operating Pressure | Orifice Diameter | Fluid Type | Connection Method | For Use With/Related Products | Mounting Type | Features | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
81529005
FLOW RESTRICT ONE-WAY FREE HANG
Crouzet
|
6,499 | 28.57500 | Active | Flow Restrictor, Fixed | One-Way | - | 15 ~ 116 PSI (1 ~ 8 bar) | 0.020" (0.50mm) | Air, Inert Gas | Push-In Connection for Tubing 5/32" (4.00mm) Dia | - | Free Hanging (In-Line) | - | Details |
|
B248+AFRX24-S N4
SPRING RETURN,24V,ON/OFF,SW,NEMA
Belimo
|
58 | 869.85000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
VBF3J31SRC/M
3-WAY ACTUATED CONTROL BALL VALV
Honeywell
|
23 | 2257.54000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
VSVA-B-M52-MH-A1-1R5L
SOLENOID VALVE
Festo Corporation
|
10 | 191.11000 | Active | Solenoid Valve | - | - | 44 ~ 116 PSI (3 ~ 8 bar) | - | Air, Inert Gas, Liquid | Threaded | - | Sub-Base Mount | Supply Voltage 24VDC | Details |
|
B338
CCV, 3-WAY, SS TRIM, 1-1/2", CV
Belimo
|
58 | 205.20000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
BM-92-533-HNR-157
5/3-WAY, ELECTRICALLY OPERATED P
AIRTEC Pneumatics
|
10 | 147.90000 | Active | Solenoid Valve | 5/3 | - | 44 ~ 116 PSI (3 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount | Supply Voltage 230VAC | Details |
|
VBF3JT1SRA/M
3-WAY ACTUATED CONTROL BALL VALV
Honeywell
|
23 | 1883.69000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
B312B
CCV, 3-WAY, BRASS TRIM, 1/2", CV
Belimo
|
58 | 63.45000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
SOL2A1
VALVE SOLENOID 1/2" BSP NO 24VDC
Sensata-Cynergy3
|
4,367 | 196.11000 | Active | Solenoid Valve | 2/2 Normally Open, One-Way | - | 1 ~ 218 PSI (0.1 ~ 15 bar) | - | Inert Gas, Liquid | Threaded 1/2" BSP | - | Free Hanging (In-Line) | Supply Voltage 24VDC | Details |
|
BM-91-534-HNR-127
5/3-WAY, ELECTRICALLY OPERATED P
AIRTEC Pneumatics
|
10 | 126.53000 | Active | Solenoid Valve | 5/3 | - | 44 ~ 116 PSI (3 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount | Supply Voltage 230VAC | Details |
|
VBF2K31SRC/M
2-WAY ACTUATED CONTROL BALL VALV
Honeywell
|
23 | 2849.60000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
BM-91-310-HNR-157
3/2-WAY NC, ELECTRICALLY OPERATE
AIRTEC Pneumatics
|
10 | 73.65000 | Active | Solenoid Valve | 3/2 Normally Closed | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount | Supply Voltage 230VAC | Details |
|
81551001
SUB-BASE ROD MOUNT
Crouzet
|
2 | 69.15000 | Active | Sub-Base | - | - | - | - | - | Push-In Connection for Tubing 5/32" (4.00mm) Dia | Sequencer | Rod Mount | - | Details |
|
VBF3J11S0D/M
3-WAY ACTUATED CONTROL BALL VALV
Honeywell
|
23 | 1528.03000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
VBF2J11SRC/M
2-WAY ACTUATED CONTROL BALL VALV
Honeywell
|
23 | 1979.86000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
B215HT455
HTCCV,0.5",2 WAY,4.55 CV
Belimo
|
58 | 79.20000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
81921501
POSITION DETECT 3/2 NC CHAS MNT
Crouzet
|
17 | 41.89000 | Active | Position Detector | 3/2 Normally Closed | Round (Pin Plunger) | 1 ~ 116PSI (0.1 ~ 8 bar) | 0.106" (2.70mm) | Air, Inert Gas | Push-In Connection for Tubing 5/32" (4.00mm) Dia | - | Chassis Mount | Operating Force 18N | Details |
|
81503025
LOGIC YES ELEMENT SUB-BASE MOUNT
Crouzet
|
10 | 46.67000 | Active | Logic Element | LOGIC YES | - | 30 ~ 116 PSI (2 ~ 8 bar) | 0.106" (2.70mm) | Air, Inert Gas | - | - | Sub-Base Mount | Pressure Indicator | Details |
|
GRLA-1/8-QS-6-MF-D
ONE-WAY FLOW CONTROL VALVE
Festo Corporation
|
2 | 26.92000 | Active | Flow Restrictor, Adjustable | One-Way | - | 3 ~ 145 PSI (0.2 ~ 10 bar) | - | Air, Inert Gas, Liquid | Threaded | - | Sub-Base Mount | - | Details |
|
BM-92-312-HNR-132
3/2-WAY NO, ELECTRICALLY OPERATE
AIRTEC Pneumatics
|
5 | 70.80000 | Active | Solenoid Valve | 3/2 Normally Open | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount | Supply Voltage 24VDC | Details |
|
VBF3JS1S0B/M
3-WAY ACTUATED CONTROL BALL VALV
Honeywell
|
23 | 1384.00000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
VBF2L41S0B/M
2-WAY ACTUATED CONTROL BALL VALV
Honeywell
|
23 | 2727.57000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
VBF2JU1S0D/M
2-WAY ACTUATED CONTROL BALL VALV
Honeywell
|
23 | 1111.95000 | Active | - | - | - | - | - | - | - | - | - | - | Details |
|
OS-1/8-B
OR GATE
Festo Corporation
|
10 | 83.50000 | Active | Logic Element | LOGIC OR | - | 15 ~ 145 PSI (1 ~ 10 bar) | - | Air, Inert Gas, Liquid | Threaded | - | Sub-Base Mount | - | Details |
Submit your RFQ and our team will source it for you.