| Mfr Part # | Qty | Price | Product Status | User Configuration | Type | Number of Positions | Voltage - Input | Power (Watts) | Voltage - Isolation | Efficiency | Features | Operating Temperature | Size / Dimension | Height | Approval Agency | Standard Number | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
UX4S0
CONFIG PWR CHASSIS 600W 4 SLOT
Advanced Energy
|
4,509 | 282.26000 | Active | - | Medical | 4 | 85 ~ 264 VAC, 120 ~ 380 VDC | 600 W | 4 kV | 91% | Conformal Coating, Fan Fail, Reverse Fan, Ruggedized, Temperature Alarm | -40°C ~ 70°C (With Derating) | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE | - | Details |
|
UX6-04
CONFIG POWER CHASSIS
Advanced Energy
|
1,708 | 319.06000 | Active | - | Medical | 6 | 85 ~ 264 VAC | 1200 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -40°C ~ 70°C (With Derating) | 10.24" L x 5.00" W (260.0mm x 127.0mm) | 1.59" (40.40mm) | CE | - | Details |
|
CX06S-0000-S-B
CONFIG POWER CHASSIS 600W 4 SLOT
Advanced Energy
|
18 | 315.32000 | Active | - | Medical | 4 | 85 ~ 264 VAC | 600 W | 4 kV | 94% | - | -40°C ~ 85°C (With Derating) | 8.50" L x 4.50" W (215.9mm x 114.3mm) | 1.50" (38.1mm) | CE | - | Details |
|
UX4-D4
CONFIGURABLE POWER SUPPLY
Advanced Energy
|
3,286 | 264.95000 | Active | - | Medical | 4 | 85 ~ 264 VAC | 600 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -40°C ~ 70°C (With Derating) | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | - | Details |
|
XZC-01
CONFIG POWER CHASSIS
Advanced Energy
|
19 | 527.10000 | Active | - | Medical, Low Noise | 6 | 85 ~ 264 VAC | 1200 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.24" L x 5.00" W (260.0mm x 127.0mm) | 1.59" (40.40mm) | CE, cURus | - | Details |
|
XFCSD3
CONFIGURABLE POWER SUPPLY
Advanced Energy
|
15 | 755.68000 | Active | - | Standard | 6 | 85 ~ 264 VAC | 1000 W | 3 kV | 90% | - | -55°C ~ 70°C (With Derating) | 10.55" L x 5.00" W (268.0mm x 127.0mm) | 1.00" (25.4mm) | CE | - | Details |
|
XZB-01
CONFIG POWER CHASSIS
Advanced Energy
|
20 | 504.24000 | Active | - | Medical, Low Noise | 6 | 85 ~ 264 VAC | 900 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.24" L x 5.00" W (260.0mm x 127.0mm) | 1.59" (40.40mm) | CE, cURus | - | Details |
|
XVDC01
CONFIGURABLE POWER SUPPLY
Advanced Energy
|
15 | 502.02000 | Active | - | Medical | 6 | 85 ~ 264 VAC | 1200 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.24" L x 5.00" W (260.0mm x 127.0mm) | 1.59" (40.40mm) | CE, cURus | - | Details |
|
XKB-02
CONFIGURABLE POWER SUPPLY
Advanced Energy
|
14 | 299.79000 | Active | - | Standard, Low Noise | 4 | 85 ~ 264 VAC | 400 W | 3 kV | 89% | Fan Fail, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | - | Details |
|
XQB-01
CONFIG POWER CHASSIS
Advanced Energy
|
1 | 431.21000 | Active | - | Standard, Low Noise | 6 | 85 ~ 264 VAC | 900 W | 3 kV | 90% | Fan Fail, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.24" L x 5.00" W (260.0mm x 127.0mm) | 1.59" (40.40mm) | CE, cURus | - | Details |
|
XFNS01
CONFIGURABLE POWER SUPPLY
Advanced Energy
|
5 | 648.73000 | Active | - | Standard | 6 | 85 ~ 264 VAC | 1000 W | 3 kV | 90% | - | -40°C ~ 70°C (With Derating) | 10.55" L x 5.00" W (268.0mm x 127.0mm) | 1.00" (25.4mm) | CE | - | Details |
|
XCE-04
CONFIGURABLE POWER SUPPLY
Advanced Energy
|
10 | 458.99000 | Active | - | Standard | 6 | 85 ~ 264 VAC | 1340 W | 3 kV | 90% | Fan Fail, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.55" L x 5.00" W (268.0mm x 127.0mm) | 1.59" (40.40mm) | CE, cURus | - | Details |
|
LPM616-CHAS
CONFIG PWR CHASSIS 1600W 6 SLOT
Bel Power Solutions
|
2 | 783.12000 | Obsolete | - | Standard | 6 | 85 ~ 264 VAC | 1600 W | 4.24 kV | 86% | - | -20°C ~ 70°C (With Derating) | 11.13" L x 5.00" W (282.8mm x 127.0mm) | 1.60" (40.64mm) | CE, cCSAus, NEMKO | - | Details |
|
UX4R
CONFIG POWER CHASSIS 600W 4 SLOT
Advanced Energy
|
7,455 | 223.36600 | Active | - | Medical | 4 | 85 ~ 264 VAC | 600 W | 4 kV | 90% | Ruggedized | -40°C ~ 70°C (With Derating) | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | - | Details |
|
XMCC01
CONFIGURABLE POWER SUPPLY
Advanced Energy
|
1,425 | 301.71000 | Active | - | Medical | 4 | 85 ~ 264 VAC | 600 W | 4 kV | 89% | Fan Fail, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | - | Details |
|
XTAS01
CONFIG POWER CHASSIS 200W 4 SLOT
Advanced Energy
|
5 | 340.42000 | Active | - | Standard, Ultra Quiet | 4 | 85 ~ 264 VAC, 120 ~ 380 VDC | 200 W | 3 kV | 89% | Conformal Coating, Fan Fail, Reverse Fan, Ruggedized, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | - | Details |
|
UX4S
CONFIG POWER CHASSIS 600W 4 SLOT
Advanced Energy
|
9,173 | 235.55000 | Active | - | Medical | 4 | 85 ~ 264 VAC | 600 W | 4 kV | 90% | Conformal Coating, Ruggedized | -40°C ~ 70°C (With Derating) | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | - | Details |
|
UX4-02
CONFIGURABLE POWER SUPPLY
Advanced Energy
|
8,382 | 260.64000 | Active | - | Medical | 4 | 85 ~ 264 VAC | 600 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -40°C ~ 70°C (With Derating) | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | - | Details |
|
XVE-04
CONFIGURABLE POWER SUPPLY
Advanced Energy
|
45 | 532.90000 | Active | - | Medical | 6 | 85 ~ 264 VAC | 1340 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.55" L x 5.00" W (268.0mm x 127.0mm) | 1.59" (40.40mm) | CE, cURus | - | Details |
|
XLB-02
CONFIG POWER CHASSIS 400W 4 SLOT
Advanced Energy
|
8,858 | 254.30000 | Active | - | Standard | 4 | 85 ~ 264 VAC, 120 ~ 380 VDC | 400 W | 3 kV | 89% | Conformal Coating, Fan Fail, Reverse Fan, Ruggedized, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | - | Details |
|
XLD-D3
CONFIGURABLE POWER SUPPLY
Advanced Energy
|
6,100 | 324.01000 | Active | - | Standard | 4 | 85 ~ 264 VAC | 750 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.55" L x 3.50" W (268.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | - | Details |
|
XMB-03
CONFIGURABLE POWER SUPPLY
Advanced Energy
|
8,557 | 292.39000 | Active | - | Medical | 4 | 85 ~ 264 VAC | 400 W | 4 kV | 89% | Fan Fail, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | - | Details |
|
XRB-01
CONFIG POWER CHASSIS
Advanced Energy
|
2,707 | 331.95000 | Active | - | Medical, Low Noise | 4 | 85 ~ 264 VAC | 400 W | 4 kV | 89% | Fan Fail, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | - | Details |
|
XMC-04
CONFIGURABLE POWER SUPPLY
Advanced Energy
|
7,476 | 291.27000 | Active | - | Medical | 4 | 85 ~ 264 VAC | 600 W | 4 kV | 89% | Fan Fail, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | - | Details |